19:599 Loss of control process [...]. Possible causes: 1. The control process has unexpectedly died. Check crash dump or core file. 2. The communication to the control process machine [...] might have gone down due to network errors. 3. If the machine [...] is a cluster, it may have failed over. 4.

Article ID: 63604

Article Type: Troubleshooting

Last Modified:

This article provides guidance on handling error 19:599 Loss of control process [...]. Possible causes.

Symptoms

Data Recovery or Data Protection jobs in progress fail with 19:599 Loss of control process [...]. Possible causes: 1. The control process has unexpectedly died. Check crash dump or core file. 2. The communication to the control process machine [...] might have gone down due to network errors. 3. If the machine [...] is a cluster, it may have failed over. 4. The machine [...] may have rebooted.

Causes

This error indicates that the executable on the client has stopped responding to requests from the Commserve and/or Media Agents.

Causes include: A crashed process A locked process (due to another application such as an Anti Virus) Intermittent Network connectivity issues Blocked Ports

Resolution

To resolve this issue: