Article ID: 68242
Article Type: Troubleshooting
Last Modified:
This article describes the resolution for error message 32:487 [...] Please check mount paths on the library [...].
Backup operations go into a Waiting status with error code 32:487.
Error Code: [32:487] Description: Insufficient disk space. Available mount paths are not enabled for write or have met reserved space limit. Enable/add more mount paths or add more disk space to existing mount paths. Please check mount paths on the library [LIBRARY_NAME]. Source: cvcommserve, Process: MediaManager
When the data path for a given job(s) has either insufficient space or no available mount paths with Read/Write access, jobs will enter a Waiting status with error code 32:487.
The error code will indicate which library is affected. The following can be checked to resolve this issue:
1. Navigate to the affected library and confirm that there is sufficient space available to continue backup operations:
2. Navigate to the affected library and confirm that all enabled mount paths have Read/Write access. If the only available mount path(s) have only Read access, backups will not be able to run, regardless of free space:
3. Run a Data Retention Forecast and Compliance report to help determine whether insufficient space is the result of improper retention settings.