With versions 11.26 or 11.28, if ransomware protection is enabled backups may fail and disk libraries hosted on a UNC path may go offline

Article ID: 77144

Article Type: Troubleshooting

Last Modified:

When upgrading to 11.26 or 11.28 with ransomware protection enabled, or when enabling ransomware protection on these versions, backups may fail and/or disk libraries or mount paths hosted using a UNC path may go offline.

Symptoms

On the Media Agent hosting the index an/or UNC mount path, you may see the following errors in the DlpAlerts.log log file on the Media Agent



### ALERT: BlockOpen [\?\Volume{0000000-0000-0000-0000-000000000000}\IndexCache\CV_Index\...\ScanInfoTot.cvf], ImageName [\?\Volume{a726834a-0000-0000-0000-501f00000000}\Program Files\Commvault\ContentStore\Base\cvd.exe], AccountName [NT AUTHORITY\SYSTEM], CreateDisposition [0x5]
### ALERT: BlockOpen [\?\Volume{0000000-0000-0000-0000-000000000000}\IndexCache\CV_Index\...\ScanInfoTot.cvf], ImageName [\?\Volume{a726834a-0000-0000-0000-501f00000000}\Program Files\Commvault\ContentStore\Base\cvd.exe], AccountName [NT AUTHORITY\SYSTEM], CreateDisposition [0x5]
### ALERT: BlockOpen [\?\Volume{0000000-0000-0000-0000-000000000000}\IndexCache\CV_Index\...\ScanInfoTot.cvf], ImageName [\?\Volume{a726834a-0000-0000-0000-501f00000000}\Program Files\Commvault\ContentStore\Base\cvd.exe], AccountName [NT AUTHORITY\SYSTEM], CreateDisposition [0x5]


Resolution

Maintenance release updates are available to resolve this issue, which can be obtained from the Commvault store. Use the table below to identify the right maintenance release version to install:

Version Hotfix Minimum Release
11.26 Hotfix 3687 11.26.31 or higher
11.28 Hotfix 1950 11.28.8 or higher
1 Commvault Way, Tinton Falls, NJ 07724 Sitemap | Legal Notices | Trademarks | Privacy Policy